Electric Utility --> Electric Charging Management Center:
electric charging utility info
Definitions
electric charging utility info (Information Flow): Information about the status and health of the electric charging network from the utility's perspective, including any grid issues or outages that electric charging users should be aware of.
Electric Utility (Source Physical Object): The 'Electric Utility' is the local provider of electricity through an electric power distribution network
Electric Charging Management Center (Destination Physical Object): The 'Electric Charging Management Center' provides management services for one or more electric vehicle charging stations used to charge hybrid and all-electric vehicles. This includes public charging stations that support consumers, workplace charging stations, and fleet charging stations using plug in (level 1, 2, fast charge, etc.), or inductive charging methods. The center interfaces with traveler information providers to support payment of charging and to disseminate information about the availability and status of their chargers and to coordinate reservations by drivers for the use of a charger. The center also interfaces with the appropriate electric utility that supplies electricity for its chargers to coordinate demand on the power grid.
Included In
This Triple is in the following Service Packages:
This triple is associated with the following Functional Objects:
This Triple is described by the following Functional View Data Flows:
This Triple has the following triple relationships:
None |
Communication Solutions
- (None-Data) - Secure Internet (ITS) (43)
- (None-Data) - Apache Kafka (44)
- (None-Data) - OMG DDS (44)
- (None-Data) - OASIS MQTT (50)
- (None-Data) - OASIS AMQP (61)
Selected Solution
Solution Description
ITS Application Entity
Development needed |
Click gap icons for more info.
|
||
Mgmt
Apache Zookeeper |
Facilities
Development needed Apache Kafka Apache Zookeeper |
Security
IETF RFC 8446 |
|
TransNet
|
|||
Access
Internet Subnet Alternatives |
Note that some layers might have alternatives, in which case all of the gap icons associated with every alternative may be shown on the diagram, but the solution severity calculations (and resulting ordering of solutions) includes only the issues associated with the default (i.e., best, least severe) alternative.
Characteristics
Characteristic | Value |
---|---|
Time Context | Recent |
Spatial Context | Regional |
Acknowledgement | True |
Cardinality | Unicast |
Initiator | Destination |
Authenticable | True |
Encrypt | True |
Interoperability | Description |
---|---|
Regional | Interoperability throughout the geopolitical region is highly desirable, but if implemented differently in different transportation management jurisdictions, significant benefits will still accrue in each jurisdiction. Regardless, this Information Flow Triple should be implemented consistently within a transportation jurisdiction (i.e., the scope of a regional architecture). |
Security
Information Flow Security | ||||
---|---|---|---|---|
Confidentiality | Integrity | Availability | ||
Rating | Moderate | Moderate | Moderate | |
Basis | Management flows should be concealed as part of defense-in-depth. | This flow should be correct and timely so the station can be properly managed, or customers may not be able to charge when they need and expect to. | This flow should be correct and timely so the station can be properly managed, or customers may not be able to charge when they need and expect to. |
Security Characteristics | Value |
---|---|
Authenticable | True |
Encrypt | True |