US: SAE Other J2735 - Local Unicast Wireless (1609.2)

Description:

This solution is used within the U.S.. It combines standards associated with US: SAE Other J2735 with those for V-X: Local Unicast Wireless (1609.2). The US: SAE Other J2735 standards include upper-layer standards required to implement V2X information flows that do not yet have fully specified functionality and performance charcateristics. The V-X: Local Unicast Wireless (1609.2) standards include lower-layer standards that support local-area unicast wireless solutions applicable to North America, such as WAVE DSRC, LTE-V2X, LTE, Wi-Fi, etc.

Relevant Regions:

Comm Profile: V-X: Local Unicast Wireless (1609.2)

Comm Class: LAN - Local Area Network

Standards in Profile:

Data Profile: US: SAE Other J2735

Standards in Profile:

Solution Issues Severity: 12

The severity issue score calculation only includes issues associated with standards that are included by default.

Solution Issues:

Default Severity Name Type Description
True Low Data not defined in standard format ITS Info Gap The definition of data concepts should conform to ISO 14817-1 to promote reuse among ITS.
True Medium Uncertainty about trust revocation mechanism Security Gap The mechanisms used to prevent bad actors from sending authorized messages is unproven.
True High Application specification not defined ITS Info Gap The logic, performance, and application security rules are not defined for this information flow.
False Low Relatively new technology Standardization Gap The standard is finalized but has not been widely deployed. Deployment experience may result in further revisions in the technology, although it is expected that the standards group will make reasonable efforts to make any changes backwards compatible.
False Medium Overlap of standards Overlap Multiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.
False Medium Regulatory Permission Needed Standardization Gap Deployment of this standard requires regulatory approval, which is currently subject to significant delays.
False High Regulatory Issue Standardization Gap Deployment of this standard is subject to regulatory approval, which is not currently expected to be granted for deployments in the near-term.

Solution to Triples

This solution is used on the following information flow triples: