roadside_signal_monitoring
This data flow sent from processes within Provide Device Control to indicate the results and status of monitoring for the conditions of the signal controller. This may indicate that the roadside equipment has detected the signal controller has a conflict in the signal states it has transmitted.
Sub Data Flows
- Primitive Element
Parent Data Flows
- None
Associated PSpecs/Terminators
- 1.2.7.7 - Process Vehicle Safety and Environmental Data for Output
- 1.2.7.16 - Process Signal Control Conflict Monitoring